Should Carrier Heat Pump Reversing Valve Be Energized in Heat or Cool?

Published in Heat Pump Control 3 mins read

For most Carrier heat pump systems, the reversing valve is energized when the system is operating in cooling mode.

When configuring a Carrier heat pump system, the reversing valve's default setting is typically to be energized during cooling operation. This means that power is supplied to the valve to change its state specifically when there is a demand for air conditioning. Conversely, during heating operation, the valve is usually de-energized, allowing it to remain in its factory default position.

This setup is a common characteristic across many Carrier heat pump models. The electrical connection responsible for activating the reversing valve often utilizes the orange (O) wire from the thermostat. When this 'O' wire is connected to the designated O/B terminal on the heat pump or its control board, it signals the system to activate the reversing valve's output, thus initiating the cooling cycle.

Key Aspects of Carrier Reversing Valve Operation

Understanding how the reversing valve functions is critical for proper installation, thermostat configuration, and troubleshooting of Carrier heat pump systems.

  • Default State: In a typical Carrier heat pump, the reversing valve rests in a "normal" or de-energized state when the system is operating in heating mode.
  • Cooling Activation: When the thermostat calls for cooling, power is supplied to the reversing valve, usually through the orange 'O' wire. This energization causes the valve to shift, redirecting refrigerant flow to enable the heat pump to absorb heat from indoors and release it outdoors, thereby cooling the living space.
  • Common Wiring: The orange (O) wire is the standard connection for controlling the reversing valve in Carrier heat pump applications. It should be connected to the O/B terminal on the control board or thermostat.

Practical Considerations for Installation and Troubleshooting

Knowing whether the reversing valve is energized in heating or cooling is vital for ensuring your system operates correctly.

Operation Mode Reversing Valve State (Carrier Typical) Thermostat Signal
Cooling Energized 'O' wire active
Heating De-energized 'O' wire inactive
  • Thermostat Configuration: It is essential to configure your thermostat to energize the 'O' terminal for cooling, as this aligns with the typical Carrier system design. Mismatched thermostat settings (e.g., a thermostat set to energize the valve for heating) can lead to the heat pump operating in the incorrect mode, such as blowing warm air when cooling is desired, or cool air when heating is needed.
  • Troubleshooting Steps: If your heat pump is not providing the correct type of conditioned air (e.g., heating instead of cooling, or vice-versa), one of the initial diagnostic steps should involve checking the reversing valve's wiring and verifying the thermostat's configuration for the 'O' or 'O/B' terminal setting.

This specific operational design allows Carrier heat pumps to efficiently switch between heating and cooling functions as environmental conditions and homeowner preferences change.