What is a Tripping Motor?

Published in Motor Protection Systems 5 mins read

A tripping motor refers to an electric motor that has automatically shut down due to the activation of a protective electrical device. This occurs when a fault or abnormal condition causes a sudden change in the motor's current, leading a protective switch or circuit breaker to automatically disconnect the power supply. This automatic disconnection, or "tripping," is a crucial safety mechanism designed to prevent damage to the motor, associated machinery, and the electrical system, as well as to protect personnel from hazards.

Understanding Motor Tripping

Motor tripping is not a malfunction of the motor itself but rather a response by its protective circuitry. When a motor or its electrical line experiences a failure, such as an overload, short circuit, or voltage imbalance, the electrical current can surge or become unstable. Sensing these sudden changes, the protective switch acts instantly to cut off power, safeguarding the entire system.

This protective action is essential for:

  • Preventing Motor Damage: Overcurrents or overheating can permanently damage motor windings, bearings, and insulation.
  • Ensuring Electrical Safety: It prevents electrical fires, electrocution risks, and damage to the power distribution infrastructure.
  • Protecting Equipment: Connected machinery is also protected from potential damage caused by motor failure or erratic operation.
  • Maintaining System Integrity: It isolates the fault, preventing it from cascading and affecting other parts of the electrical system.

Common Causes of Motor Tripping

Several factors can lead to a motor tripping. Observing any abnormalities in the motor and identifying its main symptoms can help pinpoint the exact cause.

Cause Description Typical Symptoms/Indicators
Overload The motor attempts to draw more current than its design rating. Excessive heat, slow acceleration, humming sound, increased load.
Short Circuit An unintended low-resistance path in the electrical circuit. Immediate trip, loud bang, burning smell, visible arc/flash.
Overcurrent Sustained current above the motor's rated capacity (often due to overload). Motor running hot, breaker tripping after some time.
Phase Loss/Imbalance One or more phases of a three-phase supply are missing or unequal. Motor vibrating, humming, overheating, reduced power.
Ground Fault Current flowing through an unintended path to the ground. Immediate trip, potential for shock, earth leakage detection.
Bearing Failure Worn or damaged bearings increase mechanical friction. Loud grinding/squealing noises, vibration, excessive heat near bearings.
Voltage Fluctuations Sags, surges, or spikes in the incoming power supply. Erratic motor operation, flickering lights, tripping during voltage events.
Mechanical Obstruction Something physically impeding the motor's rotation. Straining noises, lack of movement, excessive current draw.
Insulation Breakdown Deterioration of the motor's internal electrical insulation. Burning smell, smoke, short circuit trip.

Key Symptoms to Observe

When a motor trips, it's crucial to observe its condition and surroundings for any abnormalities. These symptoms provide vital clues for troubleshooting:

  • Sudden Stoppage: The most obvious symptom is the immediate cessation of motor operation.
  • Actuated Protective Device: The circuit breaker or overload relay will be in the "tripped" or "off" position.
  • Unusual Noises: Humming, buzzing, grinding, or squealing sounds before the trip.
  • Unusual Smells: A distinct burning smell (like burnt insulation or wiring).
  • Excessive Heat: The motor casing, especially near bearings or windings, feeling unusually hot to the touch.
  • Vibration: Excessive or unusual vibration during operation leading up to the trip.
  • Smoke or Sparks: Visible smoke or sparks from the motor or control panel.
  • External Damage: Visible damage to wiring, conduits, or the motor casing.

Troubleshooting a Tripped Motor

When a motor trips, follow a systematic approach to identify and resolve the issue safely:

  1. Prioritize Safety: Disconnect all power to the motor and associated machinery before inspection. Use lockout/tagout procedures.
  2. Reset the Protective Device: Attempt to reset the circuit breaker or overload relay once. If it trips again immediately, do not force it.
  3. Inspect for Obvious Faults:
    • Check for loose or burnt wires, especially at terminals.
    • Look for any physical obstructions preventing the motor's rotation.
    • Feel for excessive heat on the motor casing, bearings, and control components.
    • Listen for unusual noises if the motor was running before the trip.
    • Smell for any burning odors.
  4. Check Power Supply: Verify that the incoming voltage matches the motor's rating and is stable (check all phases for three-phase motors).
  5. Measure Current Draw: If possible, use an ammeter to measure the motor's current draw under load after a successful reset. Compare it to the motor's nameplate rating.
  6. Evaluate Load: Determine if the motor is overloaded. This could be due to a mechanical issue with the driven equipment, improper sizing, or increased process demands.
  7. Inspect Bearings: Check for excessive play, noise, or heat in the motor bearings.
  8. Consult a Professional: If the cause is not readily apparent or if the motor trips repeatedly, consult a qualified electrician or motor technician.

Preventing Future Tripping Incidents

Regular maintenance and proper system design are key to minimizing motor tripping:

  • Proper Sizing: Ensure the motor is correctly sized for its application and load.
  • Regular Maintenance: Implement a preventive maintenance schedule including lubrication, cleaning, and inspection of electrical connections.
  • Overload Protection: Ensure thermal overload relays are correctly sized and set for the motor's full-load current.
  • Voltage Monitoring: Install voltage monitoring devices in areas prone to power fluctuations.
  • Environmental Control: Protect motors from excessive dust, moisture, and extreme temperatures.
  • Vibration Analysis: Periodically monitor motor vibration to detect bearing or alignment issues early.

Understanding why a motor trips and how to respond safely is vital for operational efficiency and equipment longevity.